私たちについて私たちについて

Our Product

  • TOP
  • Sensing device - Simultaneous measurement of heat and vibration
ASM (Cutting version)
ASM

ASM (Cutting version)

Real-time measurement of temperature & vibration during machining to support the determination of optimal cutting conditions and tool life prediction.

Sensing deviceSimultaneous heat and vibration
FEATURE
Real-time monitoring enabled by a wireless measurement systemReal-time monitoring enabled by a wireless measurement system

Real-time monitoring enabled by a wireless measurement system

POINT 01

Display and record temperature and acceleration data during machining in real time

POINT 02

Amplifier, A/D converter, controller, and wireless transceiver are integrated into the tool holder

POINT 03

Intuitive display and recording software

*The software can be installed and used on Windows.
Specification

Tool holder

Sha

BT30, BT40, HSK63A: 20,000 rpm
HSK100A: 10,000 rpm

Max rotational speed (*1)
(Chuck)

ER: 20,000 rpm
SL, FM: 10,000 rpm

Balance during rotation

G2.5 or less (*2)

※1 Speed is limited by the lower value of the shank and chuck combination.
e.g.1:BT30-ER25 20,000 rpm/e.g.2:BT40-FM25.4 10,000 rpm
※2 Side lock (SL) is not included when considering the maximum speed of the holder alone.
ER: Taper collet 16° taper conforming to standard DIN6499/ISO15488
SL: Side lock
FM: Face mill arbor

Frequency response curve

Sensor part

Common
Power source

3.7V Lithium ion secondary battery (Built-in device)

Continuous availability Time

24 hours or more

24 hours or more
※May be shorter depending on usage and environment.

Recharge time

Up to about 2.5 hours

Sampling rate

About 100ms(10Hz)

Use frequency bands

Frequency band of 2.4 GHz

Communication Range

Approximately 20m or less (no obstruction)

Temperature
Temperature measuring point

1 point (can be indicated on the tool rotation axis)

Sensor type

Φ0.5 sheathed thermocouple K type (JIS class 2 equivalent)

Thermocouples other than 40.5 are also available (need consultation)

Range of
temp. measuring

0~1000 C

Acceleration
Detectable direction

Translation direction to rotation axis [X], rotation direction [R]

Measurable range

X direction:3 to 600 m/s²
R direction:600 to 120,000 rad/s²

Evaluation index

Effective value m/s² (Integration time about 100 ms)

DEVICE CONFIGURATION